Options (special manufacture): Screw terminals |


|
VACUUM SWITCH TYPE 0150 CANNOT BE USED AS A PRESSURE SWITCH! |
|
Warning! When using with oxygen, the relevant accident-prevention regulations must be observed. In addition, we recommend that a maximum operating pressure of 1,000 kPa (145 PSI) is not exceeded. We reserve the right to change technical specifications & prices without prior notice. |
|
Vacuum Switches |
|
|
Model 0150 |
Model 0151 |
|
Body Material |
Aluminum body |
Brass body |
|
Ranges |
-10 / -100 kPa 3-30” HG |
-20 / -100 kPa 6-30” HG |
|
Max. Pressure Rating |
2000 kPa (290 PSI) |
2000 kPa (290 PSI) |
|
Contact |
Change-over |
Normally Open or Normally Closed |
|
Contact Rating |
Resistive: 6 A @ 24 VDC & 3 A @ 220 V Inductive: 6 A @ 24 VDC & 0.5 A @ 220 V |
42 V (100 VA switching power) |
|
Hysteresis |
Approximately 10 kPa |
- |
|
Protection |
IP65 |
IP65 (terminals IP00) |
|
Max. Operation |
200 / min |
200 / min |
|
Mechanical Life |
106 operations @ ≤ 20 bar |
106 operations @ ≤ 20 bar |
|
Temperature Range |
-20 to 120° C |
-5 to 120° C |
|
Seal Material |
ECO (epichlorohydrin rubber) |
Viton |
|
Connection |
1/4” BSP female |
1/8” BSP female |
|
Adjustment Ranges |
Contact |
Part No. |
|
-20 / -100 kPa 6-30” HG |
Normally Open |
515 415 003 |
|
-20 / -100 kPa 6-30” HG |
Normally Closed |
515 515 003 |
|
|
||
|
Rubber cap w. dual cable duct |
662 100 003 |
|
|
Rubber cap w. single cable duct |
662 101 003 |
|
|
Switch setting to customers’ specification |
99 100 660 |
|
|
Adjustment Ranges |
Part No. |
|
-10 / -100 kPa 3-30” HG |
0150 45615 4 001 |
|
|
|
|
Switch setting to customers’ specification |
99 100 660 |